Especificación de PVC de 40 Mil

Propiedad Método de Prueba Requerimiento
Espesor ±5% ASTM-D1593 .040"
Peso Específico (mín.) ASTM-D792 1.20
Módulo a 100% - kN/m ancho, mín. ASTM-D882 7
Tracción - kN/m ancho, mín. ASTM-D882 17
Elongación a Ruptura (%, mín.) ASTM-D882 430
Rasgado Graves (N/m., mín.) ASTM-D1004 44
Resistencia al Enterramiento (% cambio máx.) ASTM-G160  
     1. Factor a Ruptura   5
     2. Elongación a Ruptura   20
     3. Elongación Módulo a 100%   20
Resistencia a Grieta por Frío (°C) ASTM-D1790 -29
Estabilidad Dimensional (% cambio máx.) ASTM-D1204 3
Extracción de Agua (%, máx.) ASTM-D1239 .020
Volátiles  (%, máx.) ASTM-D1203(A) 0.50
Resistencia Hidrostática (kPa, mín.) ASTM-D751(A) 830
Especificaciones Mínimas para Uniones en Planta de EPI:
Resistencia al Desgarro, - kN/m ancho, mín. ASTM-D882 2.6
Resistencia al Corte, - kN/m ancho, mín. ASTM-D882 14